Kistler-Morse KM Microcell Bolt-On User Manual

Page 10

Advertising
background image

Figure 3-3. Microcell™ Mounting Arrangements on Legs.

HORIZONTAL DISTRIBUTION OF
MICROCELL™ SETS

Microcell™ sets are placed on each support leg.
Refer to Figure 3-3 for the mounting locations for
each shape.

VERTICAL LOCATION OF MICROCELL™
SETS

Note

Microcell™ locations may be adjusted up to
12 in (305mm) vertically to avoid obstacles. If
adjusting locations, maintain the configuration
of the Microcell™ set (i.e., if one Microcell™ in
the set is moved from its ideal location, move
the other(s) as well).

COLUMN LEGS WITHOUT X-BRACES
See Figure 3-4.

If the free leg distance is between 12 in (305mm)
and 11 ft (3.4m), mount the Microcell™ sets at
mid-height of the free leg.

If the free leg distance is more than 11 ft (3.4m),
mount the Microcell™ sets at 5 ft 6 in (1.7m) above
the foundation.

If the free leg distance is less than 12 in (305mm),
this is a special application situation. Consult
Kistler-Morse

®

before proceeding further.

Figure 3-4. Vertical Location of Microcell™

Sets for Legs Without X-Braces.

COLUMN LEGS WITH X-BRACES

See Figure 3-5.
If the free leg distance is 12 in (305mm) or more, mount

the Microcell™ sets at mid-height of the free leg.

Measure the free leg between the bottom of the bottom

X-brace or horizontal brace and the top of the

foundation.