Kistler-Morse KM Microcell Bolt-On User Manual

Page 8

Advertising
background image

A. Proceed to TESTING WITH A DIGITAL
MULTIMETER (DMM) to determine the
resistance values for that Microcell™,

and

B. Contact Kistler-Morse

®

for assistance

after determining the resistance values
and before proceeding with installation.

CAUTION

Replace Micrcells™ in packing tubes until ready
to install.

Figure 2-1. Kistler-Morse

®

Test Meter.

TESTING WITH A DIGITAL MULTIMETER (DMM)
Follow this procedure to test the Microcell™ sets
if you do not have a Kistler-Morse

®

Test Meter or

the readings using the Test Meter were outside the
specifications:

1. Set the DMM resistance scale to

accommodate a measured range up to

20,000Ω.

2. Put one DMM lead on the Microcell™ white

wire and the other lead on the red wire. Place

the Microcell™ on a stable surface. Verify the

resistance is within the following limits:

3” standardized Microcell™ (light blue cover):

8,300Ω - 8,700Ω

2” standardized Microcell™ (dark blue cover):

1,800Ω - 2,200Ω

3. Put one DMM lead on the Microcell™ white

wire and the other lead on the black wire.

Place the Microcell™ on a stable surface.

Verify the resistance is within the following

limits:

3” standardized Microcell™ (light blue cover):

8,300Ω - 8,700Ω

2” standardized Microcell™ (dark blue cover):

1,800Ω - 2,200Ω

4. Repeat Steps 2 and 3 for each Microcell™. If

either reading for any Microcell™ is outside

these specifications, contact Kistler-Morse

®

for

assistance before proceeding with installation.

CAUTION

Replace Micrcells™ in packing tubes until ready
to install.

4

Advertising