Wiring microcell™ sets to junction box – Kistler-Morse KM Microcell Bolt-On User Manual

Page 27

Advertising
background image

Note

Junction box mounting hardware is not
supplied by Kistler-Morse

®

. Kistler-Morse

®

recommends #8-32 socket head cap screws
and flat washers. The instructions below reflect
this recommendation.

1. Remove the junction box cover.
2. See Figure 4-11. Hold the junction box at the

previously marked mounting location. Mark

the mounting holes.

3. Drill and tap the mounting holes with a #29 drill

bit and #8-32 tap.

4. Mount the junction box with #8-32 socket head

cap screws and flat washers. Tighten the

screws until snug. Replace the junction box

cover and screws if not ready to begin wiring

to ensure that no moisture enters the junction

box.

Figure 4-11. Junction Box Mounting.

Figure 4-12. Inserting Microcell™ Cable Through

Watertight Fitting and Cap.

WIRING MICROCELL™ SETS TO
JUNCTION BOX

Note

A. Junction box PCB 63-1135-03 is used for

Microcell™ sets on beams.

Ensure you

have this PCB in the junction box

(See Figure 4-13).

B. The four small holes in the bottom of the

junction box are for wiring the Microcells™

to the junction box.

1. Remove the junction box cover.
2. See Figure 4-12. Place a plastic washer on

a watertight fitting. Thread the Microcell™

cable through a cap and watertight fitting.

Leave an adequate length of cable between

the Microcell™ and fitting to provide a drip

loop (See Figure 4-13).

3. Spread a generous bead of sealant around the

sides of the watertight fitting.

CAUTION

Only use Sikaflex 1A polyurethane sealant or
Dow Corning RTV 738 or RTV 739.
Other
sealants may contain acetic acid, which is
harmful to sensors and electronics.

4. See Figure 4-13. In the bottom of the junction

box, locate one of the four small holes closest

to the terminal being used for that Microcell™.

Screw the waterright fitting into the hole.

Figure 4-13. Wiring Microcells™ to Junction Box.

23

Advertising