5. Loosen the screw securing the template and

rotate the template until the two tap guides line

up with the drilled holes. Push the #8-32 tap

into one of the tap guide holes to align the

template. Retighten the screw securing the

template.

6. Using the #8-32 tap, thread the two holes

through the template tap guides. Tap to a

minimum

5

/

8

” (16mm) depth, full threads.

Remove the template from the leg.

7. If installing a rosette array, repeat Steps 1

through 6 for the horizontal Microcell™.

8. Remove burrs from all the holes created.

MOUNTING MICROCELL™ SETS

CAUTION

Do not install Microcells™ in the rain. Do not
trap moisture under the environmental cover.

1. Wipe down a 5 in by 2¼ in (127mm by 57mm)

surface, centered on the template mounting

hole, with degreaser. This cleans the bare

metal and adjacent mounting surface for the

environmental cover.

2. Apply a thin coat of Kistler-Morse

®

rust

inhibitor to the bare metal surface for the

vertical Microcell™.

CAUTION

Do not apply rust inhibitor beyond this area, or
the environmental cover will not adhere
properly.

3. Connect the Microcell™ red, black, and white

wires to the corresponding terminals on the

Kistler-Morse

®

Test Meter. Turn on the power

to the Test Meter and set the Simulate/Test

Switch to the Test position.

Note

If a Kistler-Morse

®

Test Meter is not available,

refer to Appendix C (Alternate Method for
Checking Output) before proceeding.

4. With the cable end down, align a vertical

Microcell™ with its mounting holes. Fasten the

Microcell™ loosely to the leg using the two

#8-32 x

5

/

8

” socket head cap screws and

washers.

Do not tighten the screws. If the

voltage goes outside the range -100mV to

+100mV, immediately loosen the screw(s).

Note

3” Microcells™ for vertical and horizontal
installation are slightly different. 3” Microcells™
for horizontal installation are labeled
“Horizontal.” 3” Microcells™ for vertical
installation are not labeled.

CAUTION

For proper installation, tighten each screw until
the T-handle driver flexes in torsion ¼ turn past
the point where the screw stops turning.
Repeat this flexing procedure several times to
ensure the screw is tight. When both screws
are tight, the voltage must be in the range
-100mV to +100mV. Follow the procedure in
Steps 5 through 7 to achieve this goal.

5. Using the T-handle driver, slowly tighten the

top screw. While turning the T-handle driver,

monitor the test meter carefully. If the

voltage goes outside the range -100mV to

+100mV while tightening, stop immediately

and evaluate the following:

A. If the voltage jumped outside the range

-100mV to +100mV, it may indicate a burr

or rough surface. Remove the screws

holding the Microcell™ to the leg. Check

for and remove burrs and surface

roughness (refer to SURFACE

PREPARATION for removing surface

roughness). Repeat Steps 1through 5.

B. If the voltage gradually moved outside the

range -100mV to +100mV, slowly loosen

the screw until the voltage is within range

again and proceed to Step 6.

6. Repeat Step 5 for the bottom screw. If the

voltage is outside the range -100mV to

+100mV, attempt to bring the reading within

range by loosening the screw being torqued,

tightening the other screw, or some

combination of loosening and tightening. If

you have difficulty staying within the range, try

turning each screw ¼ turn at a time until both

screws are tightened.

9