17

Set Curing Conditions

The activation energy is calculated automatically

on basis of the retention times at the lower

and upper temperature. It is the basis for the

calculation of the equivalence time.
For calculating the Equivalent Holding Time, you

can either enter the activation energy of the material

directly, or you can have the program do the

calculation for you:
For this purpose, enter the required temperature

as well as the duration time into the Low and High

boxes as the program needs two reference values

for calculating the activation energy. Next, look at

the tables and compare the calculated equivalent

time with the required duration time of the reference

temperature. This will give you a measure for the

quality of the hardening process.
With the option box „Calculate Above Minimum“ you

can exclude temperature values below the minimum

temperature from the calculation of the equivalent

time. However, due to the logarithmic calculation

method, the results are unlikely to differ significantly.