Table 11 — Pump Electrical Data

FLA — Full Load Amps

Table 12 — CCN Communication Bus Wiring

4. The RJ14 CCN connector on TB3 can also be used, but is

only intended for temporary connection (for example, a

laptop computer running service tool).

NON-CCN COMMUNICATION WIRING — The 30XA units

offer several non-CCN translators. Refer to the separate installa-

tion instructions for additional wiring steps.

FIELD CONTROL OPTION WIRING — Install field con-

trol wiring options. Some options, such as 4 to 20 mA demand

limit that requires the energy management module, may

require that accessories be installed first (if not factory

installed) for terminal connections.
DUAL CHILLER LEAVING WATER SENSOR — If the dual

chiller algorithm is used and the machines are installed in par-

allel, an additional chilled water sensor must be installed for

each chiller. Install the wells in the common leaving water

header. See Fig 39. DO NOT relocate the chiller’s leaving

water thermistors. They must remain in place for the unit to

operate properly.

The thermistor well is a

1

/

4

in. NPT fitting for securing the

well in the piping. The piping must be drilled and tapped for

the well. Select a location that will allow for removal of the

thermistor without any restrictions.

Once the well is inserted, install the thermistors. Insert the

thermistor into the well until the o-ring reaches the well body.

Use the nut on the thermistor to secure the thermistor in place.

Once the thermistor is in place, it is recommended that a

thermistor wire loop be made and secured with a wire tie to the

chilled water pipe. See Fig. 39.

For dual chiller control a CCN bus must be connected

between the two modules. See the Carrier Comfort Network

Communication Bus Wiring section for additional information.

PUMP

HP

UNIT VOLTAGE

V-Hz (3 Ph)

HYDRONIC SYSTEM (SINGLE OR DUAL)

FLA (Each)

30XA

UNIT SIZE

5

230-60

11.6

090-160

200-60

12.6

460-60

5.8

575-60

4.6

380-60

7.0

7.5

230-60

17.4

090-160

200-60

18.5

460-60

8.7

575-60

7.0

380-60

10.4

10

230-60

23.0

090-160

200-60

25.0

460-60

11.5

575-60

9.2

380-60

14.0

15

230-60

34.0

090-160

200-60

36.7

460-60

17.0

575-60

14.0

380-60

21.0

MANUFACTURER

PART NUMBER

Regular Wiring

Plenum Wiring

Alpha

1895

American

A21451

A48301

Belden

8205

884421

Columbia

D6451

Manhatten

M13402

M64430

Quabik

6130

IMPORTANT: A shorted CCN bus cable will prevent

some routines from running and may prevent the unit

from starting. If abnormal conditions occur, disconnect

the machine from the CCN. If conditions return to

normal, check the CCN connector and cable. Run new

cable if necessary. A short in one section of the bus

can cause problems with all system elements on the

bus.

(+) (COM) (-) SHIELD

CCN

RED

WHT

BLK

CCN

LEN

(+) (COM) (-) SHIELD

CCN

RED

WHT

BLK

CCN

LEN

TO NEXT
DEVICE

(+) (COM) (-) SHIELD

CCN

RED

WHT

BLK

CCN

LEN

SHIELD

LEGEND

Fig. 38 — TB3 — CCN Wiring