Step 6 — Install Accessories —

A number of acces-

sories are available to provide the following optional features

(for details, refer to the Controls and Troubleshooting guide

shipped with the unit).
ENERGY MANAGEMENT MODULE — The energy man-

agement module is used for any of the following types of

temperature reset, demand limit and ice features:
• 4 to 20 mA inputs for cooling set point reset and capacity

limit (requires field-supplied 4 to 20 mA generator)

• 0 to 10 v output for percentage total capacity running

• 24 v discrete outputs for shutdown and running relays

• 10k space temperature input

Discrete inputs for occupancy override, demand limit

switch 2 (step 1 demand limit is wired to the base board,

requires field-supplied dry contacts), remote lockout switch

and ice done switch (requires field-supplied dry contacts).
REMOTE ENHANCED DISPLAY (OR TOUCH PILOT™

DISPLAY) — For applications where remote monitoring of

the equipment is required; the remote enhanced display (or

Touch Pilot display) provides an indoor display, capable of

monitoring any equipment on the Carrier Comfort Network

®

(CCN) bus. A CCN bus is required.
LOW AMBIENT TEMPERATURE OPERATION — If out-

door ambient operating temperatures below 32 F (0° C) are

expected, refer to separate installation instructions for low-

ambient operation using the low ambient temperature head

pressure control accessory.
MINIMUM LOAD ACCESSORY — Contact your local

Carrier representative for more details if a minimum load ac-

cessory is required for a specific application. For installation

details, refer to separate installation instructions supplied with

the accessory package.
UNIT SECURITY/PROTECTION ACCESSORIES — For

applications with unique security and/or protection require-

ments, several options are available for unit protection.

Security grilles and hail guards are available. Contact a local

Carrier representative for more details. For installation details,

refer to separate installation instructions supplied with the

accessory package.
COMMUNICATION ACCESSORIES — A number of com-

munication options are available to meet any requirement.

Contact your local Carrier representative for more details. For

installation details, refer to separate installation instructions

supplied with the accessory package.
SERVICE OPTIONS — Two accessories are available to aid

in servicing 30XA units: a ground fault convenience outlet

(GFI-CO) and a remote service port.

The GFI-CO is a convenience outlet with a 4-amp GFI

receptacle.

The remote service port is housed in a weather-proof enclo-

sure with a communication port to plug in the Navigator™

device.

Contact your local Carrier representative for more details.

For installation details, refer to separate installation instructions

supplied with each accessory package.
CONTROL TRANSFORMER — The control transformer

accessory eliminates the need for a separate power supply.

Step 7 — Leak Test Unit —

The 30XA units are

shipped with a complete operating charge of R-134a (see

Tables 1A and 1B) and should be under sufficient pressure to

conduct a leak test.

Perform a leak test to ensure that leaks have not developed

during unit shipment. Dehydration of the system is not required

unless the entire refrigerant charge has been lost. There are

several O-ring face seal fittings utilized in the oil line piping. If

a leak is detected at any of these fittings, open the system and

inspect the O-ring surface for foreign matter or damage. Do not

reuse O-rings. Repair any leak found following good refrigera-

tion practice.

Step 8 — Refrigerant Charging

DEHYDRATION — Refer to Carrier Standard Service Tech-

niques Manual, Chapter 1, Refrigerants, Sections 6 and 7 for

details. Do not use compressor to evacuate system.

5/8 in. HEX

6" MINIMUM

CLEARANCE FOR

THERMISTOR

REMOVAL

1.188 in.

2.315 in.

1/4-18 NPT

Fig. 39 — Dual Leaving Water Thermistor Well (Part No. 00PPG000008000A) and

Dual Leaving Water Thermistor (Part No. 00PPG000008105A)

a30-3999

WIRE TIE

LOOP

THERMISTOR WIRE

AND SECURE

TO CHILLED WATER PIPE

INSERT THERMISTOR UNTIL

O-RING MEETS THE

THERMISTOR WELL BODY.

a30-4000

IMPORTANT: These units are designed for use with

R-134a only. DO NOT USE ANY OTHER refriger-

ant in these units.

CAUTION

DO NOT OVERTIGHTEN THESE FITTINGS. Over-

tightening will result in O-ring damage.