All plu sales read (x) report, Zone plu sales read (x) report, Daily cashier read (x) report – Toshiba TEC MA-85-100 User Manual
Page 74
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
EOl -11072
All PLU Sales Read (X) Report
Use MA Key.
PLU
The drawer does not open.
Report
Starts
See page 83 for
sample format.
Sales data of all the PLUs with any sales
data recorded.
(PLUS with zero sales data are skipped.)
Zone PLU Sales Read (X) Report
Use MA Key.
X
REG
OFF
SET
PLU Code that
starts the required
zone (range) for
this report
(max. 3 digits).
@/FOR
The Start PLU Code must be equal to or
smaller thart the End PLU Code. When equal,
the data of only one PLU is read.
PLU
PLU Code that
ends the zone
(max. 3 digits).
The drawer does not open.
Report
Starts
See page 83 for
sample format.
Sales data of the PLUs of the codes in the range of
the designated zone.
(PLUs with zero sales data are skipped.)
Daily Cashier Read (X) Report
(option; refer to Chapter 18)
(available when Cashier Signing Method has been selected)
(operable in signed-OFF condition only)
Use MA Key.
X
REG
OFF
SET
□
LOG
RECEIPT
The drawer opens
&
Cashier Code
1 to 4
(assigned by the r;-------------------- --------------------
store) of the
occurs;
cashier whose data [• Is the register signed-
is to be read. ' [ff
1« Wrong code?
Report
Starts
See page 84 for
sample format.
Sales data recorded by
the cashier
- 74 -