Security functions, Reset anti-passback for all cards [g – Keri Systems HPP-100 User Manual

Page 33

Advertising
background image

HPP-100 Hand-Held Programmer

Revision 3.3

27

_ _ _ _ _ _ _ _ _ _

Press . . . [0] [0] [7] [9] [3] [3] [4] [2] [7] [4]

[LVL] [SND] [CLR]

0 0 7 9 3 3 4 2 7 4

At this point, you have a choice.

You may . . .

Press . . . [SEND]

and all the default card/slot time zone and system configuration attributes will be
transferred as is.

Or you may assign a time zone value for the card being entered. To assign a time zone
value, you must know the time zone value you wish to apply.

To assign a time zone value of 3:

Press . . . [LVL]

ENTER CODE

LEVEL : _

Press . . . [3] [SEND]

Security Functions

Reset Anti-Passback for All Cards [G]

Anti-passback is used to ensure one-card/one-way access into and then out of a
controlled area. An authorized card presented to the access reader will allow access, but
will not work again for access until one of three things happens: the card has been
presented to an egress reader, 24 hours have passed, or the Master Control Unit has
been reset with the Reset Anti-Passback command. The Reset Anti-Passback for All
Cards command resets the passback status for all cards in the system. This will allow a
card previously considered inside the access area to be reused for access once.