5.2 Settings

The NORAC UC5 settings are displayed on the main run screen. To change these settings on
the Integra or VERSA, press on the boom image to display the boom height control options

screen as shown in Figure 8. To change the settings on the InSight and EDGE, click the
settings button.

Figure 8: Boom Height Control Settings Screen (Integra™ Display)

Mode:
The Mode button allows the system to be changed between Soil Mode, Crop Mode and Hybrid
Mode. Soil Mode allows the sensors to read a height from the spray nozzles to the ground;
whereas Crop Mode will read the height from the spray nozzles to the top of the crop canopy.
Hybrid Mode is an improved Crop Mode and is recommended in place of Crop Mode. For
more information on Crop, Soil and Hybrid Mode refer to Section 6.4.

Sensitivity:
The sensitivity can be adjusted from 1 to 10, with 5 being the default setting. A lower number
will reduce the system sensitivity. Higher settings will speed up the response and also create a
greater demand on the hydraulics.

Target Height:
The target height is the height you would like the boom to be set at when spraying. When
operating in soil mode, the target height is measured from the spray nozzles to the soil. In crop
mode the target height is measured from the crop canopy to the spray nozzles.