30

Manual Dead Zone Calibration:

In the Valve tab select the function

that you wish to calibrate.
Press the Deadzone button.

Press and hold Manual Test.
Continue to hold it until the boom
stops moving and the live reading
of the distance travelled stabilizes.
When properly tuned, the distance
travelled should be 1-2 inches (2-
5cm).
Adjust the deadzone value until the
distance travelled is 1-2” (2-5cm).
When properly calibrated, press
the check.