NORAC UC5-BC-AL Manual User Manual

Page 36

Advertising
background image


32

Manual Gain Calibration:
This test will drive the boom at full speed in the selected direction for one second. Make sure
the boom has full range of movement and if driving the boom down, make sure it is not close
to the ground. The purpose of this test is to determine the sprayer boom speeds. It is
recommended that you perform each test three times and average your readings.
From the speed measurements taken, use Table 4 to determine the appropriate gain values to
use for each function. This test will provide approximate results for gain values. Proper gain
values rely on more than just boom speed so it is highly recommended to use the automatic

gain setup if possible.

In the Valve tab select the function
that you wish to calibrate.
Press the Gain button.

Press and hold the Manual Test
button. Continue to hold it until
the boom stops moving and the
live height reading stabilizes.
Displayed is the boom speed, in

inches/second.
Use the following tables to
determine the appropriate gain
values.
Press the check button to accept
the setting.

Advertising