Test running – Perfect Aire 1PAMSH36-MZO4-16 Installation Manual User Manual

Page 24

Advertising
background image

A: Lo packed valve B: Hi packed valve
C and D are ends of indoor unit connection.

CAUTION

Gas leak check

1.

Soapy water method:

Apply a soapy water or a liquid neutral

detergent on the indoor unit connection

or outdoor unit connections by a soft

brush to check for leakage of the

connecting points of the piping. If bubbles

come out, the pipes have leakage.

2.

Leak detector

Use the leak detector to check for leakage.

15

A, B,C,D are points for one-four type.

Indoor unit

check point

Outdoor unit

check point

23

Fig.69

NOTE: The illustration is for explanation

purpose only. The actual order of A, B, C,

and D on the machine may be slightly

different from the unit you purchased. The

actual shape shall prevail.

Test running

Perform test operation after completing gas leak check at the flare nut connections and
electrical safety check.
Check that all tubing and wiring have been properly connected.
Check that the gas and liquid side service valves are fully open.
1. Connect the power, press the ON/OFF button on the remote control to turn the unit on.
2. Use the MODE button to select COOL, HEAT, AUTO and FAN to check if all the functions
work well.
3. When the ambient temperature is too low (lower than 62.6 F), the unit cannot be controlled by
the remote control to run at cooling mode, manual operation can be taken. Manual
operation is used only when the remote control is disabled or maintenance necessary.

Press the Manual control button to select the AUTO or COOL, the unit will operate under
Forced AUTO or COOL mode (see User Manual for details).
4. The test operation should last about 30 minutes.

Hold the panel sides and lift the panel up to an angle until it remains fixed with a clicking

sound.

Manual control

Button

Fig.70

Manual control

button

AUTO/COOL

TEST RUNNING