INSTALLATION INSTRUCTIONS

1. For the left-hand and right-hand piping,
remove the pipe cover from the side
panel.
2. For the rear-right-hand and rear-left-hand
piping, install the piping as shown in Fig.10.

3. Fix the end of the connective pipe. (Refer
to Tightening Connection in REFRIGERANT
PIPING CONNECTION)

Connective pipe installation

2. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.

Right-hand piping

Left-hand piping

Rear-right piping

Rear-left piping

Fig.8

Fig.9

Fig.10

4. Piping and wrapping

Bundle the tubing, connecting cable, and drain

hose with tape securely, evenly as shown in

Fig.11.

Because the condensed water from rear of the

indoor unit is gathered in evaporative drain pain

box and is piped out of room do not put anything

else in the box.

Indoor unit

Connective
pipe

Pipe room

Ponding box

Wrapping belt

Connective
cable

Drain hose

Fig.11

Connect the indoor unit first, then the

outdoor unit.

Do not allow the piping to let out from

the back of the indoor unit.

Be careful not to let the drain hose slack.

Heat insulated both of the auxiliary piping.

Be sure that the drain hose is located at

the lowest side of the bundle. Locating

at the upper side can cause drain pan

to overflow inside the unit.

Never intercross nor intertwist the power

wire with any other wiring.

Run the drain hose sloped downward to

drain out the condensed water smoothly.

CAUTION