Selecting installation place

Read completely, then follow step by step.

Indoor unit

Do not expose the indoor unit to heat or steam.

Select a place where there are no obstacles

in front or around the unit.

Make sure that condensation drainage can

be conveniently routed away.

Do not install near a doorway.

Ensure that the space on the left and right

of the unit is more than 5 inches (12cm).

Use a stud finder to locate studs to prevent unnecessary damage to the wall.

The indoor unit should be installed on the wall at a height of 7 feet (2.0 m) or more from the floor.

The indoor unit should be installed allowing a minimum clearance of 6 inches (15cm) from the ceiling.

Any variations in pipe length will/may require adjustment to refrigerant charge.

There should not be any direct sunlight. Otherwise, the sun will fade the plastic cabinet and

affect its appearance. If unavoidable, sunlight prevention should be taken into consideration.

Outdoor unit

If an awning is built over the outdoor unit to

prevent direct sunlight or rain exposure,

make sure that heat radiation from the

condenser is not restricted.

Ensure that the clearance around the back

of the unit is more than 12 inches (30cm) and left side is

more than 12 inches (30cm). The front of the unit should

have more than 7 feet (2m) of clearance and the

connection side (right side) should have more

than 24 inches (60cm) of clearance.

Do not place animals and plants in the path of the air inlet or outlet.

Take the air conditioner weight into account and select a place where noise and vibration

will not be an issue.

Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.

If the outdoor unit is installed on a roof structure, be sure to level the unit.

Ensure the roof structure and anchoring method are adequate for the unit location.

Consult local codes regarding rooftop mounting.

If the outdoor unit is installed on roof structures or external walls, this may result in

excessive noise and vibration, and may also be classed as a non serviceable installation.

Rooftop installation: