7.4 Overflow Detection: (OFLO)

1. This message occurs when liquid is in danger of overflowing tank.

2. When this condition occur all power to the machine shall be shut down.

Corrective Action

1. Turn off the machine

2. Scoop out the water manually from the tank.

3. Turn on the machine, machine will operate again.

4. If the machine is still not working, contact a service agent.

7.5 Ultrasonics Overheating: (HOT)

This message occurs when the ultrasonics board indicates an excessive heat condition.

Corrective Action

1. Turn off the machine at power point.

2. Allow to cool for at least one hour.

3. Re-start machine.

4. If “HOT” display persists, contact a service agent.

7.6 Real Time Clock: (rtc)

This message occurs if the Real Time Clock (rtc) date/time in the system is considered invalid. Happens
often when the machine is not being used for a long period of time.

Corrective Action

1. Reset the date/time through the Web interface. (Read the Machine Reporting Manual, Page 7)

2. Contact a service agent.

7.7 Power up. (P-UP)

This message occurs at boot up time if a clean process was interrupted and did not complete its cycle. This
alerts the operator that instruments being cleaned in the machine may not be completely clean. May also
occur if machine was not shut down in correct manner

Corrective Action

1. Press enter and continue with the clean cycle

7.8 Water Leak. (H2OL)

Water may have entered the red control box or blue ultrasonic box or there may be a circuit/wiring failure.

Corrective Action

1. Contact a service agent.

7.9 Setting default IP values. (IP-?)

Only for MRS models and IT staff use. Corrective Action

1. Contact the facilities IT department

2. Refer to the Machine Reporting Manual, Page 11

3. Contact a service agent

S-2800 Irrigator Operating Manual