8.3 Weighing Specifications

Capacity Range:

2Lbs (1Kg) to 500,000 Lbs (250,000 Kgs)

Input Range:

0.5mV/V to 3mV/V.

Internal Counts:

10,000,000(Nom.) 16,777,215(Max.)

Display Counts:

Up to 100,000 / 10,000 recommended for stability.

Input Sensitivity:

2

µ

V per display graduation (using 2mV/V input @

10,000 display counts)
Formula: Sensitivity = ((mV/V*excitation voltage)/

Display counts)

Linearity:

.01% of full-scale capacity.

Overload:

105% of full-scale capacity.

Load Cell Excitations:(Standard): 10VDC @ .5A max.

(Up to 9-350

load cells).

Load Cell Excitation: (Optional): 10VDC @ 1.5A max.

(Up to 27-350

load cells).

Calibration:

2-step keyboard digital, or direct coefficient
entry.

8.4 Communication Specifications

Ports:

Three RS-232 Full Duplex/Individually
Configurable. Optional RS485 or 10 BaseT
Ethernet on COM1.

Baud Rate:

Port Selectable: 1200 – 115200 bps.
Up to 10Mbps on Ethernet.

Start/Stop Bits:

Fixed at 1 for all ports.

Parity:

Port selectable: Even, Odd, or None.

Word Size:

Port selectable: 7 or 8 bits.

Flow Control:

None.