2-79

Chapter 2

FUNCTIONS AND OPERATION

MASTER STATION'S FUNCTIONS AND OPERATION

5.11.3. Confirming audio trigger setting status (N-8000MS/8500MS/8600MS only)

The setting status of the Audio Trigger function can be confirmed at any Multi-Functional Master Station by

designating a Door Station.

8

2

X

X

2 0 0

: A c t i v e

L e v e l = 1 : T i m e = 1

Function designation number

Door station number

Displayed for 5 sec.

8

3

X

X

Function designation number

Door station number

8

3

X

X

Function designation number

Door station number

5.11.4. Adjusting the effectiveness of Audio Trigger Function

The effectiveness of Audio Trigger function can be adjusted by designating a Door Station at any station and

changing the setting value of the alarm detection conditions.

[Making the Audio Trigger function less effective]

If the Audio Trigger function works when not needed, change the setting value following the operation below.

• When the alarm detection method is set to “Level detection,” the sound pressure level of the specified Door

station’s Audio Trigger function can be increased by 3 dB through the operation shown below.

• When the alarm detection method is set to “Audio detection,” the set sensitivity value of the specified Door

station’s Audio Trigger function can be increased by one step through the operation shown below.

[Making the Audio Trigger function more effective]

If the Audio Trigger function does not work when needed, change the setting value following the operation

below.

• When the alarm detection method is set to “Level detection,” the detection level of the specified Door station’s

Audio Trigger function can be decreased by 3 dB through the operation shown below.

• When the alarm detection method is set to “Audio detection,” the set sensitivity value of the specified Door

station’s Audio Trigger function can be decreased by one step through the operation shown below.