Installation of remote microphone station, Desk-top installation – Toa N-8000 Series User Manual

Page 335

Advertising
background image

3-31

Chapter 3

INSTALLATION & WIRING

8. INSTALLATION Of ReMOTe MICROPhONe STATION

8.1. Desk-Top Installation

8.1.1 N-8610RM expansion with the addition of the RM-210

When adding an RM-210 Remote Microphone Extension to expand the N-8610M, use the RM-210's Extension

cable and included Linkage Bracket to link the 2 units.

Follow the procedures below.

Step 1. Turn over both the N-8610RM and the RM-210, and keep them in close contact with each other.

Step 2. Connect between the RM-210 connection terminal (EXTENSION) on the N-8610RM side and the RM

connection terminal (EXTENSION) on the RM-210 side using the extension cable supplied with the

RM-210.

In this case, install the ferrite clamp

supplied with the N-8610RM on the

extension cable as shown below.

Step 3. Link both the N-8610RM and the RM-

210 together using the Linkage Bracket B

supplied with the RM-210.

Secure the bracket with the 4 supplied

screws indicated by arrows.

Step 4. Fix both units securely using the Linkage

Bracket A (2 pieces) supplied with the

RM-210.

Secure them with the 8 supplied screws

indicated by arrows.

Tip

Follow the same procedures when linking

additional RM-210. But you need not install the

ferrite clamp on the extension cable used to

connect between RM-210s.

Notes

• Because the Linkage Bracket A is provided with 2 spare screw holes, use them to link the 2 units if the

designated screw threaded holes are damaged.

• If incorrect or loose connection is found between both units, loosen all the bracket fixing screws to disassemble

the units and then link them again with the screws.

RM-210

N-8610RM

Linkage bracket B

RM-210

N-8610RM

2

Ferrite clamp

(white, supplied with N-8610RM)

Linkage bracket A

Extension cable

(supplied with RM-210)

[Bottom]

[Bottom]

3

4

Extension cable

(supplied with RM-210)

Ferrite clamp

(white, supplied with N-8610RM)

Advertising