SYSTEM SETTINGS BY SOFTWARE

Telephone Interface: Network Settings

5-94

(4) port No.

Set the start port number to be used for each protocol.

[Web server]

Allows entry of the Web server's port number. The valid range is from 1 to 65535. The default factory setting

is 80.

[TCP port]

Allows entry of a TCP port start number other than the Web server (valid range from 1 to 65532). The

N-8000 system uses 4 consecutive ports starting with the TCP start port. The default factory setting is

5000.

The TCP port is assigned as follows.

Note

Because UDP port number 15000 is used internally by the system, the numbers from 14981 to 15000 are

not available.

[Paging port (UDP)]

Displays the UDP port number to be used when making paging using the multicast communications.

To perform settings, refer to

p. 5-121, Paging Zone Settings

.

(5) NApT compatible

When connecting a PC to the Telephone interface unit using the global IP address, mark the [Enable]

checkbox to make the items from [Network ID (6)] to [WAN port No. (8)] available for input.

Port

Web server
Call control
PC monitoring
PC control
Reservation

Port Number

Web server
Port start number + 0
Port start number + 1
Port start number + 2
Port start number + 3

Protocol

TCP
TCP
TCP
TCP
TCP

Default setting

80

5000
5001
5002
5003

Port

Reservation
Conversation

Port Number

Port start number + 0 to 3
Port start number + 4 to 19

Protocol

UDP
UDP

Default setting

5006 to 5009
5010 to 5025

[UDP port]

Allows entry of UDP port start number to be used (valid range from 1 to 65516). The N-8000 system uses

20 consecutive ports starting with the UDP start port. The default factory setting is 5006.

The UDP port is assigned as follows.