P. 5-47 – Toa N-8000 Series User Manual

Page 457

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

Multi Interface: Contact Input

5-47

5.5.5. Contact input setting

Step 1. Click "Contact Input" tab. The setting screen is displayed.

Step 2. Set each item of "Contact input."

(1) Contact input No. (Can't be edited.)

The Multi interface unit's contact input terminal number.

(2) Operation mode

Select the contact input's operation mode. The setting contents differ depending on the mode selected

here.

Input interlock level: Select this item when closing the contact output terminal in synchronization with

the contact input terminal as shown below. (The input is defined when its level

remains constant for 50 ms after change.)

Input interlock edge: Select this item when closing the contact output terminal in synchronization with

the contact input terminal as shown below. (The input is defined when its level

remains constant for 50 ms after change.)

[Input interlock level]

ON

Input

OFF

ON

Output

OFF

[Input interlock edge]

ON

Input

OFF

ON

Output

OFF

50 ms

50 ms

50 ms

50 ms

Advertising