Montage of the connecting hose:

Individual performance check of a pump head:

If the pump does not achieve the ultimate pressure:

☞ In case the diaphragms and valves have been replaced, a run-in period of several

hours is required before the pump achieves its ultimate vacuum.

If all pump heads achieve a vacuum below 85 mbar but pump does not achieve the
ultimate total pressure:
Check hose connectors between pump heads and manifolds for leaks. If necessary
recheck pump chamber.

By measuring the pressure at the inlet port of the individual
head:
➨ Use a suitable vacuum gauge (e. g. DVR 2, cat. no.: 68 29

02), make sure that it is correctly calibrated, and measure
the pressure at the inlet port. A vacuum of less than 85
mbar should be indicated.

☞ If the reading is higher, recheck the pump chamber and make

sure that the valves and the diaphragms are correctly seated
(diaphragms concentric with bore).

➨ Wind the attachment for the hose two times with PTFE bond

(only MV 10C VARIO / PC 2010 VARIO), see also ”Notes
on assembling fittings and hose connections (only
MV 10C VARIO / PC 2010 VARIO)”
.

➨ Use open ended wrench (w/f 15) to reconnect hose to el-

bow fitting.

➨ Screw in four socket head screws fixing housing cover cross-

wise (e. g. in the sequence

➀, ➁, ➂, ➃) first slightly, then

tighten.

☞ Do not tighten until head cover is in contact with housing,

torque 12 Nm.

➨ Tighten union nuts first by hand and then tighten one full

turn using open ended wrench (w/f 17).

Advertising