Cleaning and inspecting the pump heads, Pumps nt vario / pc 300x vario) – VACUUBRAND MZ 2C NT VARIO without controller (o.C.) User Manual

Page 50

Advertising
background image

page 50 of 76

The valves and diaphragms are wear parts. If the rated

ultimate vacuum is no longer achieved or in case of in-

creased noise level, the pump interior, the diaphragms

and the valves must be cleaned and the diaphragms and

valves must be checked for cracks or other damage.

All bearings are encapsulated and are filled with long-life

lubricant. Under normal operating conditions, the drive

system is maintenance free.

In demanding circumstances, it may be efficient to check

and clean the pump heads on a regular basis. In normal

use, the lifetime of the diaphragms and valves is typically

15,000 operating hours.

- Prevent internal condensation, transfer of liquids or

dust. The diaphragms and valves will be damaged if

liquid is pumped in significant amount.

- Carry out maintenance frequently if the pump is ex-

posed to corrosive media or in case of deposits.

- Regular maintenance will improve the lifetime of the

pump and also protect both users and the environment.

Service kit for ME 4C NT VARIO ................................................................696864

Service kit for MZ 2C NT VARIO / PC 3002 VARIO ....................................696869

Service kit for MD 4C NT VARIO / PC 3003/3004 VARIO ...........................696870

Service kit for MV 10C VARIO-B / MD 12C VARIO-B /

PC 301x VARIO ...........................................................................................696821

Diaphragm key (width 66 mm) ...................................................................636554

Tools required (metric):
- Torx driver T20

- 5 mm wide Allen key

- 2.5 mm wide slotted screwdriver

- Flat pliers

- Diaphragm key width 66 mm

Cleaning and inspecting the pump heads

(pumps NT VARIO / PC 300x VARIO)

Advertising