The vacuu•lan – VACUUBRAND MV 10C NT + EK User Manual

Page 44

Advertising
background image

page 44 of 92

Vacuum hose (caoutchouc) 15 mm ID (sold by meter) .............................686003

Adapter for gas ballast connection ...........................................................636193

via small flange KF DN 16

Level sensor for catchpots ...........................................................................699908

(VACUUBRAND controller CVC 3000 or VNC 2 is required).

At the inlet:

Metal hose (stainless steel) KF DN 25 (1000mm) .....................................673337

PTFE hose KF DN 25 (1000mm)..................................................................686033

Adapter small flange KF DN 25 / hose nozzle DN 15 mm (PP) ...............662808

Adapter small flange KF DN 25 / 2x connection for PTFE tube

I.D. 3/8”, O.D. 5/16” (10 / 8 mm) (PP)

incl. centring ring (with FEP coated seal ring) ............................................667052

Vacuum valve VS 25C KF DN 25 (butterfly-type valve) ...............................665008

At the outlet:

Small flange KF DN 16 / G 1/2” ...................................................................672101

Silencer G 1/2” .............................................................................................642473

For additional accessories such as vacuum valves, small-flange components,

vacuum gauges or vacuum controllers refer to www.vacuubrand.com

VCL 01

VCL-B 10

VCL 02

VCL-B 11

The VACUU•LAN

®

modules allow process-ori-

ented, flexible and cost effective connections

according to your requirements. One vacuum

pump can support several workstations. Con-

tact VACUUBRAND for details.

VACUU•LAN

®

manual flow control module VCL 01 ..................................677106

VACUU•LAN

®

shut off / manual flow control module VCL 02

677107

VACUU•LAN

®

automatic control module VCL-B 10 ..................................677208

VACUU•LAN

®

manual flow control/

automatic control module VCL-B 11 ..........................................................677209

On this page we offer only a small selection of VACUU•LAN

®

options. Please contact VACUUBRAND for further

information. Listed modules are designed for surface-mounted installation. Different catalog numbers are used for

modules designed for flush-mounting with concealed tubing.

Attention: Dust-laden gases, deposits and condensed solvent vapor can restrict

air flow out the silencer. The resultant back pressure can lead to damage of pump

bearings, diaphragms, and valves. Under those conditions, a silencer must not be

used.

Advertising
This manual is related to the following products: