PART 5
ENGINE ELECTRICAL SYSTEM

SECTION 5.7

REMOTE PANELS

Section 5.7

REMOTE PANELS

General

Optional panels are available w hich m ake it possi­

ble to start and stop the generator set from a rem ote
location in the vehicle housing the unit. The follow ing
panels and w iring harnesses are available for use w ith
w ater-cooled diesel engine units:

□ Model 9044 start/stop panel. Panel features (a) a

start/stop sw itch, (b) startup advisory lam p, (c) a
preheat sw itch, and (d) a m ounting plate.

□ Model 9047 w iring harness. This 30 foot harness

perm its the M odel 9044 start/stop panel to be con­
nected to the generator.

□ Model 9061 rem ote gauge panel. Panel m ounts (a)

a start/stop sw itch, (b) a preheat sw itch, (c) oil pres­
sure gauge, (d) a DC voltm eter, (e) coolant tem per­
ature gauge, and (0 an hourm eter.

□ Model 9118 w iring harness is 30 feet long. Harness

perm its the M odel 9061 rem ote panel to be con­
nected to the generator.

Model 9044 Start/Stop Panel

GENERAL:

The Model 9044 Rem ote Panel is show n in Figure

1, below . The panel includes (a) a stop/start sw itch, (b)

a preheat sw itch, and (c) a generator run lam p.

PANEL MOUNTING;

The rem ote panel is designed to be flush-m ounted

to a w all in the vehicle that houses the generator. Figure
2 show s the w all cutout dim ensions for m ounting the
panel.

OPTIONAL REMOTE W IRING HARNESS;

Use the Model 9047 w iring harness to install the

Model 9044 rem ote panel. The 6-w ire harness is 30 feet
long and includes a connector plug w hich m ust be
plugged into the generator’s rem ote panel receptacle
(Figure 3).

^GENERAC R.V. GENERATOR^

QEN.

Q RUN

>

STOP

START

I PREHEAT

30 SEC. MAX

Figure 1. M odel 9044 Rem ote Panel

Figure 4. M odel 9044 Panel Com ponents

PAGE 5.7-1