Measurement – Sekonic L-358 User Manual

Page 16

Advertising
background image

-12-

1-2

Aperture Priority mode

1. Hold down the Mode set button !0 and turn the Jog wheel

t to select aperture priority mode .

2. Turn the Jog wheel to set the desired f stop

value.

3. Press the Measuring button !5 to make a measure-

ment.
Release the Measuring button to complete the
measurement. The measured value (shutter
speed) at the time will be displayed.

While pressing the Measuring button, the
meter measures continuously until it is
released.

Reference:

It is possible to switch between full,1/2 or 1/3 F stop values by setting DIP switches 3 and
4.
You can set f stops from F1.0 to F90 (full f stops)
The measured shutter speed value is displayed either full or half stop increments on the
analog scale.(1/3 stop increments is not possible.)
After measurement, the shutter speed corresponding to the F stop is displayed when the
F stop is changed.

5. Measurement

1/10
shutter speed

Set f stop value

Measured shutter speed

MODE

Measured value (shutter speed)

Advertising