Measurement – Sekonic L-358 User Manual

Page 19

Advertising
background image

-15-

2.

Measuring flash light
This method of measurement can be done in the following modes; with cord, without cord, multiple
flash with cord, multiple flash without cord and Wireless flash radio triggering mode (with optional
radio transmitter module). When Measuring flash light, the shutter speed and F stop value (value
combining ambient light and flash light: total amount of light) are displayed.The ambient light and
flash light are each displayed as separate values together with the total amount of light on the
analog scale. In addition, the ratio of flash light to the total amount of light is displayed at that time
as a value in 10% steps.The flash reading is displayed as a blinking mark above the analog scale.(See
page 27 for details)

2-1 Cord Flash mode

The most positive method to assure proper synchronization and measurement of flash units.
Connect the meter to the flash with a synchronization cord. Be sure to replace Synchro termi-
nal cap @0 after your measurement.

1. Connect the flash synchro cord to the Synchro

terminal i on the exposure meter.

2. Hold down the Mode set button !0 and turn the

Jog wheel t to select cord flash mode .

3. Turn the Jog wheel to set shutter speed. When

setting shutter speed, first check the settings to
confirm that they correspond to the settings on the
camera.

4. Press the Measuring button !5 to trigger the flash.

The measured value (f stop value) will be displayed.

5. Measurement

Measured f stop value

1/10
f stop

Set shutter speed

measured f stop value
(total exposure)

POWER

ISO 1

MODE

MEMOR

Y

ISO 2

AVE./AEV

FLASHMASTER

L-358

MODE

Percentage of flash in
total exposure

Advertising