Measurement – Sekonic L-358 User Manual

Page 22

Advertising
background image

-18-

2-3

Cord multiple flash (cumulative) mode
These measurements are used when the light generated by the flash is inadequate for proper
exposure. The repeated flash pops can be accumulated until the desired aperture is displayed.
The cumulative number is infinite. Only one digit is displayed if the cumulative number is ten or
more.Display returns 0 (0=10, 1=11, 2=12 etc.)

1. Slide DIP switch 2 to MULTI (see page 8) to the

ON position.
Hold down the Mode set button !0 and turn the
Jog wheel t to select cord multiple flash (cumu-
lative) mode

.

2. Turn the Jog wheel t to set shutter speed. When setting shutter speed, first check the

settings to confirm that they correspond to the settings available on the camera.

3. Connect the Flash synchro cord to the meter's

synchro terminal i.

4. Press the Measuring button !5 to trigger a flash. The measured f stop value at that time will

be displayed. Each time this is repeated, the accumulated f stop value and the number of
cumulative flashes is displayed.

5. To clear the cumulative value,hold down Mode set button and ISO2 button y or switch to

another mode by turning the Jog wheel while pressing the mode set button.

5. Measurement

Measured f stop

1/10 f stop

Number of cumulative flashes

Set shutter speed

MODE

Percentage of
flash in total
exposure

Measured f stop value
(total exposure)

1st. time

2nd. time

3rd. time

Advertising