COMPUTER BATTERIES
The PowerTap SL has batteries in the hub and computer. Computer batteries
typically need to be changed every 400 hours of use. The computer will also
say “low bat” when the computer battery needs to be changed. This message
is displayed after a “clr” is performed. To replace computer battery (Type
CR2032), remove the computer from the mount. Remove the battery cover
on the back of the computer (use a cone wrench to remove the battery
cover), exchange the battery, and replace the cover as shown below (FIGURE
29).

TECHNICAL SPECIFICATIONS
Accuracy

+/-1.5%

Signal Transmission

Digital RF

Interval Data Storage

Unlimited

Interval Display

9 Intervals (internal recording)

Operational Temperature

0 to 40 degrees c or 32 to 104 f

Battery Life (Hub)

300 hours approx.

Battery Life (Console)

400 hours approx.

Battery Type (Hub)

Type 357 or EPX 76 (2 ea)

Battery Type (Console)

AAA type, 1.5 volt (3 ea)

Freehub fixing bolt torque

400-450 inch-lbs.

RANGE OF MEASUREMENT
Power

0-1999 Watts

Torque

0-1999 inch-lbs.

Speed

2-59 mph (3-95 KPH)

Distance

0.00 to 9999.99 (Miles)

Trip Time

0.00.00-999.99 Minutes

Cadence

40-140 RPM

Total energy

0-99999 Kilojoules

Odometer

0-99999 Miles or Kilometers

Heart Rate

0-255 BPM (Beats per Minute)