Chapter four – Heath Consultants Detecto-Pak 4 (DP) User Manual

Page 20

Advertising
background image

100786-0 Rev. D

05/09

CHAPTER FOUR

IV. CHARGING SYSTEMS

The Detecto-Pak 4 Flame Ionization Detector utilizes a 1.5 amp hour Nickel Metal

Hydride rechargeable battery pack as the source of its power. The instrument was

designed for 8 hours of continuous operation however this battery, when properly

cared for, will provide adequate power to operate the instrument for 10 plus hours

under normal conditions. In freezing conditions the battery capacity is reduced

between 10% and 20% depending on the health of the battery.

In order to give the user a means to roughly determine the battery capacity, a

Battery Test Switch is included on the Detecto-Pak 4 control panel. Pressing and

holding this switch will indicate the approximate charge level of the battery on the

instrument meter. The meter is color coded on the center scale with green indicating

adequate capacity, yellow indicating reduced capacity and a recommendation for

recharging, and red indicating questionable capacity and the need to recharge.

The instrument will continue to operate in the yellow an up to mid scale in the

red, however continuing to operate in the red means the instrument will gradually

become unstable and ultimately will loose sensitivity. Operating in the red is not

recommended.

Part of the charging system includes an approved, automatic electronically

controlled battery charger to recharge the nickel metal hydride battery. For export,

when required, a 220 VAC, 50 Hz to 110 VAC converter for your battery charger

is available. Because of a wide range of 220 VAC receptacles encountered around

the world, the customer must provide an adapter on the input side of the converter

to fit the 220 VAC receptacle.

A. NICKEL METAL HYDRIDE (NiMH) RECHARGEABLE BATTERY

Due to the nature of the battery, more energy must be put back into the

battery then is drawn from it. Normally, it requires 10 to 12 hours of

charging to completely recharge the Nickel Metal Hydride battery. Shorter

charging periods may have a negative effect on the health of the battery

and are not recommended.

13