Menu Descriptions

P a r r I n s t r u m e n t C o m p a n y

40

Moisture as Determined (MAD) Entry Mode:

This key steps through the options for entering
the moisture as determined correction value
either manually or through the touch screen or
automatically through the balance (USB) port.

Moisture as Received (MAR) Entry Mode: This

key steps through the options for entering the
moisture as received correction value either
manually or through the touch screen or auto-
matically through the balance (USB) port.

Auto Preweigh ID Controls: Accesses sub-menu,
used to automatically assign Sample ID numbers
when a series of samples are pre weighed ahead of
the time they are actually tested.

Preweigh Sample ID Controls

Automatic Preweigh ID: ON/OFF toggle for

this feature.

Automatic Preweigh ID Prefix: An entry here

will be used as a prefix for all pre-weigh
sample IDs.

Next Automatic Preweigh ID Number: Shows

the next Sample ID which will be assigned and
is used to enter the beginning Sample ID of
any series

Automatic Preweigh ID Increment: Establishes

the increment between samples.

Reporting Controls Menu

Report Width: Toggle this key to set the column
width of the printer to either 40 or 80 columns.
Select 40 when the 1758 Printer is used.

Automatic Reporting: Toggles the automatic report-
ing ON/OFF. When ON, preliminary reports will be
generated at the conclusion of the test and final
reports will be generated as soon as all of the thermo-
chemical corrections are available. When OFF, reports
will only be generated by selecting the Report key.

Auto Report Destination: Toggles to direct the
reports to the Printer or the screen display.

Individual Printed Reports: When set to ON, will
generate extra line feeds for each report printed. In
the OFF position, these extra line feeds will not be
inserted.

Edit Final Reports: When set to ON, enables the user
to revise sample weight and thermochemical correc-
tions of finalized reports from the report menu.

Recalculate Final Reports: When set to ON, causes a
recalculation of stored final reports using calibration
data and menu settings currently in the Calorimeter.

Use New EE Value in Recalculation: When set to
ON, any recalculation made will use the most recent
EE value in the calculations. In the OFF position, all
calculations will be made using the EE value which
was effective when the test was originally run.

Report Schedule: Toggles between End of Post
Period and end of Cool/Rinse. This setting deter-
mines when the report will be printed or displayed.