Major Fault indication. A red triangle is probably accompanied by a noticeable failure in
the ECD. For example, the flashlight or a laser might not be working. A major fault indicates
a subsystem failure. The ECD still may produce an NMI effect, but the ECD is no longer
functioning as intended.

Shift the CAM-Lock safety to the down (SAFE) position and then to the up (ARMED) position;
the fault may clear. If the fault does not clear, it may still be possible to use the ECD for a
short time.

If the fault did not clear, send the ECD to TASER International for repair. See the "Product
Returns" section
in this manual for instructions.

!

Critical Fault indication. A stop sign indicates a system failure. The ECD is NOT to be used.

Critical faults are rare. Shift the CAM-Lock safety to the down (SAFE) position and then to
the up (ARMED) position; the fault may clear.

If the fault does not clear, do NOT attempt to use the ECD. Send it to TASER International for
repair. See the "Product Returns" section in this manual for instructions.

NOTE: If no icons of any kind display on the CID and the CAM-Lock safety is in the up
(ARMED) position, but there is a solid red light at the top edge of the CID, then the CID has
failed. The X3 ECD may be working—check the ECD to see if the lasers and flashlight are still
operating. However, the CID is broken. Send the ECD to TASER International for repair. See
the "Product Returns" section
in this manual for instructions.

Battery Not Recognized. If you see a question mark within the battery icon of the battery
status icon this indicates that the ECD did not recognize the battery correctly. Remove the
EPM/TPM and reinsert it. If the error is still present, try another battery. If the Battery Not
Recognized icon still displays, this usually indicates that something has happened to the
battery connector inside the handle and the handle should be sent in for service. See the
"Product Returns" section
in this manual for instructions.

Stealth. When the ECD is in the stealth mode, a letter S will display in the battery icon. (See
the "Selector Switch" section
in this manual for more information about the stealth mode.)

Central Information Display (CID) Color Graphic User Interface

Circuit Status Icons

Circuit status icons indicate the degree of connection to the target. Circuit status icons are for reference
only; they are not intended to replace the need to look for visual indications or listen for other indications to
determine the subject’s connection status.

When the ECD has a good connection to the target, the good circuit completion icon is
displayed.