Horizontal dimensional data cont, Horizontal disconnect, Envision – WaterFurnace Envision2 User Manual

Page 9: Compact installation manual

Advertising
background image

9

ENVISION

2

COMPACT INSTALLATION MANUAL

Horizontal Dimensional Data cont.

2.1 in.

[5.3 cm]

KK

Disconnect Located

on this Side for a

Left Return

Disconnect
Location

Power Supply

Horizontal Shown in

Right Return Configuration

Horizontal

Models

Overall Cabinet

Water Connections

Electrical Knockouts

1

2

3

J

K

A

B

C

D

E

H

Loop

1/2 in. cond

1 in. cond

Width

Depth

Height*

In

Out

Condensate

Water FPT

Low Voltage Power Supply

009-012

in.

22.5

35.0

17.2

1.8

6.8

0.8

1/2 in.

7.1

7.1

cm.

57.2

88.9

43.7

4.6

17.3

2.0

12.7 mm

18.0

18.0

015-018

in.

22.5

42.0

19.2

1.8

6.8

0.8

3/4 in.

9.1

7.1

cm.

57.2

106.7

48.8

4.6

17.3

2.0

19.05 mm

23.1

18.0

024-030

in.

22.5

45.0

19.2

1.8

6.8

0.8

3/4 in.

9.2

7.1

cm.

57.2

114.3

48.8

4.6

17.3

2.0

19.05 mm

23.4

18.0

036-038

in.

25.5

48.0

21.2

1.8

6.8

0.8

1 in.

9.2

9.1

cm.

64.8

121.9

53.8

4.6

17.3

2.0

25.4 mm

23.4

23.1

042-049

in.

25.5

53.0

21.2

1.8

6.8

0.8

1 in.

9.2

9.1

cm.

64.8

134.6

53.8

4.6

17.3

2.0

25.4 mm

23.4

23.1

060-064

in.

25.5

61.0

21.2

1.8

6.8

0.8

1 in.

9.2

9.1

cm.

64.8

154.9

53.8

4.6

17.3

2.0

25.4 mm

23.4

23.1

070-072

in.

25.5

68.0

21.2

1.8

6.8

0.8

1 in.

9.2

9.1

cm.

64.8

172.7

53.8

4.6

17.3

2.0

25.4 mm

23.4

23.1

3/16/12

Horizontal

Models

Discharge Connection

duct fl ange installed (±0.10 in.)

Return Connection

using deluxe fi lter rack option (±0.10 in.)

PVC Size

L

M

N

P

Q

R

S

T

X

Supply Width Supply Depth

Return Depth Return Height

009-012

in.

5.9

7.2

9.5

6.0

16.4

14.5

2.0

1.4

3/4”

cm.

15.0

18.3

24.1

15.2

41.7

36.8

5.1

3.6

1.9

015-018

in.

6.7

10.5

9.4

4.9

27.4

16.6

2.0

1.4

3/4”

cm.

17.0

26.7

23.9

12.4

69.6

42.2

5.1

3.6

1.9

024-030

in.

6.7

10.5

9.4

4.9

30.4

16.6

2.0

1.5

3/4”

cm.

17.0

26.7

23.9

12.4

77.2

42.2

5.1

3.8

1.9

036-038

in.

4.9

13.6

13.2

4.6

35.4

18.6

2.3

1.4

3/4”

cm.

12.4

34.5

33.5

11.7

89.9

47.2

5.8

3.6

1.9

042-049

in.

4.9

13.6

13.2

4.6

40.4

18.6

2.3

1.4

3/4”

cm.

12.4

34.5

33.5

11.7

102.6

47.2

5.8

3.6

1.9

060-064

in.

4.9

13.6

13.2

4.6

45.4

18.6

2.3

1.4

3/4”

cm.

12.4

34.5

33.5

11.7

115.3

47.2

5.8

3.6

1.9

070-072

in.

4.9

13.6

13.2

4.6

45.4

18.6

2.3

1.4

3/4”

cm.

12.4

34.5

33.5

11.7

115.3

47.2

5.8

3.6

1.9

Horizontal units shipped with standard 2 in. (fi eld adjustable to 1 in.) open application fi lter rack extending 2.2 in. from unit and is
not suitable for duct connection, for ductable return connection applications, order the deluxe 2 in. (fi eld adjustable to 1 in.) fi lter
rail/fi lter rack which extends 3.25 in. from the unit and is suitable for duct connections.

3/16/12

Horizontal Models

KK

009-012

8.2 [20.8]

015-018

9.2 [23.4]

024-030

9.2 [23.4]

036-038

11.2 [28.4]

042-049

10.2 [25.9]

060-064

11.2 [28.4]

070-072

10.2 [25.9]

Dimensions in inches [cm]

3/16/12

Horizontal Disconnect

When using disconnect, do not use dimension K from the
standard horizontal dimensional data. Use dimension KK from
the horizontal disconnect dimensional data.