Altera PowerPlay Early Power Estimator User Manual

Page 31

Advertising
background image

Altera Corporation

3–17

May 2008

PowerPlay Early Power Estimator For Arria GX FPGAs

Using the PowerPlay Early Power Estimator

Table 3–5

describes the I/O bank parameters in the I/O section of the

PowerPlay Early Power Estimator.

Figure 3–9

shows how the V

CCIO

level is listed for each I/O bank. The

PowerPlay Early Power Estimator spreadsheet shows the I

CCIO

listed for

each bank. Select the V

CCIO

voltage in the V

CCIO

column.

Figure 3–9. V

CCIO

Listed for Each I/O Bank

Table 3–5. I/O Bank Information in the I/O Section

Column Heading

Description

V

CCI O

Select the V

CCI O

voltage for each bank. Used to cross-check selected I/O standards

in table below for warning purposes.

I

CCI O

(A)

This shows the total supply current due to the I/O pins in each I/O bank. This may be
higher than the thermal power due to current supplied to off-chip termination resistors.

Unassigned

This represents the I

CCI O

of all I/O modules not assigned to an I/O bank.

Advertising