Heat sink, Figure 3–34 – Altera PowerPlay Early Power Estimator User Manual

Page 57

Advertising
background image

Altera Corporation

3–43

May 2008

PowerPlay Early Power Estimator For Arria GX FPGAs

Using the PowerPlay Early Power Estimator

Figure 3–34. Temperature Variances

For example, location 3 is where the ambient temperature pertaining to
the device should obtained for input into the PowerPlay Early Power
Estimator spreadsheet. Points 1 and 2 are cooler than location 3; location
4 is likely close to 25

o

C. Temperatures close to devices in a system are

often in the neighborhood of 50-60

o

degrees but the values can vary

significantly. In order to obtain accurate power estimates from the
PowerPlay Early Power Estimator spreadsheet, it is very important to get
a realistic estimate of the ambient temperature near the FPGA device.

Heat Sink

When using a heat sink, the power is determined by the following
equations.

(T

J

- T

A

) /

θ

JA

= P

θ

JA

=

θ

JC

+

θ

CS

+

θ

SA

The value

θ

JC

is specific to the FPGA and can be obtained from the data

sheet. The value

θ

CS

refers to the material that binds the heat sink to the

FPGA and is approximated to be 0.1 C/W. The value

θ

SA

is obtained from

the manufacturer of the heat sink. It is important to ensure that when this
value is obtained that it is for the right conditions for the FPGA which
include analyzing the correct heat sink information at the appropriate
airflow at the device.

f

For more information on how to determine heat sink information refer to
AN 358: Thermal Management for 90-nm FPGAs and

www.altera.com

.

F

A
N

1

2

3

4

FPGA

Advertising