Chapter 4: Development Board Setup

4–3

Factory Default Switch and Jumper Settings

February 2013

Altera Corporation

Stratix V Advanced Systems Development Kit

User Guide

Figure 4–2

shows the switch locations and the default position of each switch on the

bottom side of the board.

To restore the switches to their factory default settings, perform the following steps:

1. Set DIP switch (SW4) to match

Table 4–1

and

Figure 4–2 on page 4–3

.

Figure 4–2. Default Settings on the Board Bottom (Detail)

SW6

FPGA2

MSEL

1 2 3 4

1

0

SW5

FPGA1

MSEL

1 2 3 4

1

SW8

1 2 3 4

X1 X4 X8 X16

SW7

1 2 3 4

0

0

1

0

1

SW4

1 2 3 4 5 6

FPGA1_FPP FPGA2_FPP EXTRA0 EXTRA1 CLK_EN CLK_SEL

HSMC JTAG FMC

Table 4–1. SW4 DIP Switch Settings

Switch

Board Label

Function

Default

Position

1

FPGA1_FPP

Switch 1 has the following options:

When on (0), FPP x8 is enabled to configure
FPGA1 from flash location 0 and FPGA2 from flash
location 1. FPGA1 MSEL (SW5) pins and FPGA2
MSEL (SW6) pins must be set correctly.

When off (1), no design is configured to FPGA1 or
FPGA2 using FPP x8.

On

2

FPGA2_FPP

On

3

EXTRA0

Off

4

EXTRA1

Off

5

CLK_EN

Switch 5 has the following options:

When on (0), the on-board oscillator is disabled.

When off (1), the on-board oscillator is enabled.

Off

6

CLK_SEL

Switch 6 has the following options:

When on (0), the SMA input clock is selected.

When off (1), the programmable oscillator clock is

selected.

On