D*ap lm 4, Web gui – audio processor – fail over – Junger Audio D*AP LM2 / D*AP LM4 - Digital Audio Processor User Manual

Page 29

Advertising
background image

25

D*AP LM 4


Link

[Linked / Unlinked]

defines the coupling of the control circuits in order to maintain the
listening balance for correlated signals and to provide a grouping of the
setup parameters for two channel signals.

Input

[Enable / Disable]

here there are numerous pre-conditioning options for the input audio
signal(s).

Mute

will mute all channels controlled by the respective column.

Input Gain (dB)

sets the gain [-80 … +20]

Input HPF (Hz)

high pass filter (6dB/oct) cut off frequency [OFF, 2, 20, 40, 80, 120]

Input LPF (kHz)

low pass filter (6dB/oct) cut off frequency [OFF, 15, 20, 22]

Input Delay (ms)

[1 … 2000]


Web GUI – AUDIO PROCESSOR – Fail Over


Fail Over – Set the conditions for detecting loss of main audio in order to trigger switching to the secondary
source.


For the program input 1L/1R, the source for the fail over circuit can be the second program input
(input 2L/R). The Mode switch will select the respective signal path.

Fail Over 1L/1R

MODE

The Fail Over output can be permanently connected to :

its program input 1L/1R

the second program input 2L/2R

or may be set to AUTO

Advertising