34

D*AP LM 4


Web GUI – AUDIO PROCESSOR – Output


Output – The final screen in this section allows for the adjustment of numerous audio parameters directly on
the final output signal.

Link

[enable / disable]

Output

[enable / disable]

Mute

[on / off]

Attenuation (dB)

[-80.0 … 0.0]

Mono

[Stereo, L+R, LL, RR]

Output Delay (ms)

[0 … 2.000]


Web GUI – EVENTS – Trigger – Trigger Configuration


EVENTS - In a broadcast facility, there are often requirements to integrate the Digital Audio Processor into
the automation system in order to facilitate functions such as remotely re-calling presets, firing GPO
commands etc. The events tab is where all relevant parameters can be set up.

A Trigger is the logical combination of up to two trigger sources. The Trigger may launch one or more
events. An event runs like a flip-book inside the D*AP. This powerful technology spans from simply recalling a
certain parameter to the complete reconfiguration of the LM 4. But it also enables several fail over scenarios
where the LM 4 will automatically react to the system and/or parameter status

Trigger
– As a default, 8 standard trigger conditions are available. These can be configured to determine
actions resulting from combinations of hotkey, GPI, network commands, parameter values, active events,
other active trigger etc. stimulus :