3wiring – Tempest Thunder User Manual

Page 15

Advertising
background image

Thunder Enclosure User Manual

page

15

3

Wiring

Electrical Preparation



All electrical work must be carried out by a properly licensed electrician. Failure to observe

this point will void the factory warranty for the Tempest Enclosure and possibly the equipment

housed inside.

1 Before starting work, switch off power to the branch circuit, carefully following lockout and

tag-out procedures. Failure to do so could cause serious injury or death.

2 Two electrical junction boxes will be required within a short distance of the Thunder

enclosure for:

AC supply wiring

DMX control wiring

Your Thunder enclosure is supplied fitted with two cable entry points, for Power and DMX signal

cables.

The cable entries are suitable for use with standard conduit fittings. US size ½”, international

20mm. Tempest recommends the use of flexible, outdoor-rated conduit for the last few feet (1m) to

the enclosure.

All junction boxes must be installed in accordance with local electrical codes and should be located

near the permanent installation of the enclosure. Each junction box requires a length of flexible

conduit, long enough to reach from the junction box to the enclosure conduit fittings. Leave slack

for positioning of enclosure, and enough space behind the enclosure for ventilation.

The AC supply must be protected by a fuse or circuit breaker of a rating suitable for the equipment.

Thunder Enclosure Power Requirement:

Standard Thunder enclosures with MiniDEC control

20W

Thunder enclosures with DEC3 control option

520W

The user may connect the fan and the equipment to the same switched supply, or run them

separately, according to need (see below).

Note that for temporary in stallation, the conduit fittings may be replaced with outdoor-rated cable

entry glands, at the user’s discretion.