Connect AC Wiring to MiniDEC Controller

Single Feed Operation

Split Feed Operation

Single Feed Wiring

Feed the controller with a single maintained supply. The light must be switched off when needed using

the lighting control system.

Thunder ships configured for single feed wiring operation.

DO NOT CONNECT SINGLE FEED WIRING TO THE OUTPUT OF A DIMMER.

Dual Feed Wiring

You may switch off the supply to the light without interfering with the cooling fan operation. Connect

feeder wires as shown, AND CUT THE COPPER LINK ON THE MiniDEC BOARD IN TWO PLACES, AS

SHOWN. Fan circuit should be maintained 24/7.

NEUTRAL

GROUND

LIVE (Fan)

LIVE (Light and Fan)

LIVE (Light)

CUT LINK 2

PLACES FOR

SPLIT FEED

OPERATION

NEUTRAL

GROUND