Tempest Thunder User Manual

Page 33

Advertising
background image

Thunder Enclosure User Manual

page

33

Control Interface

LED Indicators

Heater

ON (Green)

Heater is ON, to maintain lower temperature

level or to prevent condensation

Fan

ON (Green)

Lamp is ON, or Temperature is HIGH and

Fan is cooling enclosure. Short burst when lamp

off indicates fan moving air to stabilize

temp/humidity

Lamp On

ON (Green)

Current sensing shows lamp is ON

Lamp hour counter is running

OFF

Current sensing shows lamp is OFF

Lamp hour counter is not running

Lamp Relay

ON (Green)

Lamp relay is closed (normal)

Luminaire power receptacle is energized

ON (Red)

Lamp relay is open due to over-temperature

event. Luminaire power receptacle is isolated.

Temp

FLASHING

(Green)

Temperature is below lower temp setting

ON (Green)

Temperature is in normal range

ON (Amber)

Humidity is above target limit

ON (Red)

Temperature is above top setting

FLASHING (Red)

Temperature is above Trip level

Luminaire power is isolated

DMX

OFF

DEC3.3 is in BASIC Mode – DMX not used. OR

DEC3.3 is in Monitor or Control Mode and no

valid DMX or RDM packet has been detected.

ON (GREEN)

Good DMX or RDM data packet received.

ON (RED)

Control Mode: DMX Fail. A previously good DMX

signal has failed.

Monitor Mode: No RDM information being

received (this is normal)

Advertising