Tempest Hurricane User Manual

Page 14

Advertising
background image

Hurricane Enclosure User Manual

page 14

The DEC3.2 mode or personality may be configured form the Front Panel or by using an RDM

control. In all configurations, the fixture inside the Tempest enclosure may also be an RDM

enabled device.

Basic Mode

This is the way your DEC3.2 controller will normally ship from the factory. It will

be set up for standalone operation, with settings that will be appropriate for most

installations.

In most cases, Basic Mode will work fine for you. You only need to change it if you

will be using DMX or RDM (and if these terms are not familiar to you, you

probably won’t) or if you have to deal with extreme climate conditions.

You may set temperature and other parameters while using Basic Mode.

Monitor Mode

The enclosure operates independently, and automatically, requiring no user

intervention. Users may set parameters such as temperature and humidity

thresholds, and monitor sensor information and DEC status at the DEC3.2 using

the display, or remotely, using RDM over a DMX512 network. In this mode, the

DEC3.2 does not need to “see” any DMX to operate.

Control Mode

This mode has all of the Monitor Mode features plus control of the Lamp Relay

using a single DMX slot at the address configured as the DEC3.2 DMX start

address.

A DMX slot value (level) > 75% will cause the fixture to be powered and less than

25% will disconnect the power form the fixture. On DMX fail, the Lamp Relay will

default to power the fixture, unless it detects a thermal condition that would

cause it to isolate power from the fixture/projector.

DMX control of the Lamp Relay has the useful attribute of enabling the user to

remotely force a hard reset of the fixture by controlling power to it. This mode is

recommended for show-control applications, where it is desirable to have power

control of the internal fixture and accidental loss of the DMX data is very unlikely

to occur.

To force a hard fixture reset, take the enclosure’s DMX channel to zero (or any

level below 25%), allow time for the fixture’s power supplies to fully discharge,

then restore the enclosure’s DMX channel to full (or a level above 75%).

Service Mode

This mode is intended for test and service use only, giving the user direct control

of the Lamp Relay, fan and heater controls over three DMX slots. Users may NOT

override any of the controls in an unsafe direction – for example, if the DEC3.2

has determined the enclosure is over-temperature and has switched off the power

to the fixture, the Lamp Relay may not be controlled by DMX. In this sense, DMX

Advertising