Hurricane Enclosure User Manual

page 44

Important – RDM and RDM Integration

RDM (Remote Device Management) is an ANSI standard that adds bidirectional discovery and

status monitoring to a standard DMX network connection. No additional wiring is required for

RDM operation.

DEC3’s RDM implementation allows system integrators to set up remote control and status

monitoring of all attributes and sensors, including:

Temperature

Humidity

Lamp Current

Elapsed Lamp Hours

Lamp Relay Status

Fan Relay Status

Heater Relay Status

DMX Status

DMX Start Address

DMX Personality (RDM Mode)

Device Type

Device Label

Software Version

Tempest Lighting warrants that its RDM products are compliant to the RDM standard, but does not

directly support RDM system integration. Tempest Lighting will however provide introductions to

qualified RDM system integrators for customers requiring assistance in this area. Links are

provided on the Tempest Lighting web site (www.tempestlighting.com).

DEC-3 RDM Supported parameters

DEVICE -INFO
IDENTIFY -DEVICE
DMX -START -ADDRESS
SOFTWARE -VERSION-LABEL
PARAMETER -DESCRIPTION
QUEUED -MESSAGE
STATUS -MESSAGES
STATUS -ID -DESCRIPTION
CLEAR -STATUS -ID
MANUFACTURER -LABEL
DEVICE -LABEL
SENSOR -DEFINITION
SENSOR -VALUE
LAMP - HOURS
DEVICE -MODEL -DESCRIPTION
SLOT -INFO
SLOT -DESCRIPTION
DMX -PERSONALITY
DMX -PERSONALITY -DESCRIPTION
TOP TEMP
BOTTOM TEMP
CUTOFF TEMP