Split or common supply wiring, Common feed operation (factory default), Split feed operation – Tempest Hurricane User Manual

Page 19

Advertising
background image

Hurricane Enclosure User Manual

page 19

Split or Common Supply Wiring

IMPORTANT: Tempest enclosures with any generation of DEC control MUST be powered

24/7, in order to protect equipment from condensation and temperature extremes.

The AC power feed must be adequate and appropriately fused/protected for the greater of the

projector/light fixture load (see manufacturer’s instructions) and the Tempest enclosure (see

enclosure manual). Since the enclosure heater(s) never operate when the projector/fixture lamp is

on, it is NOT necessary to rate the power service for the SUM of the enclosure and the

projector/light fixture.

Common Feed operation (factory default)

Tempest Enclosures are normally supplied wired for common electrical supply for the enclosure

(DEC3.2) and the projector/light fixture to be enclosed.

Connect incoming power to the terminals labeled MAINS:

(E) Earth/Ground (L) Live

(N) Neutral

Split Feed Operation

Split Feed allows you to run the projector/light fixture independently of the enclosure. The

enclosure must be powered 24/7.

DEC3.2 normally ships from the factory with circuit card power links in place for a common

electrical supply to feed the enclosure and the projector/fixture inside it.

To feed the enclosure and projector separately, you will

need to remove the bridging links on the controller

circuit board as shown in the illustration, before

connecting to mains power.

Use a pair of small side cutters to cut the bridging links

from the circuit board, taking care to not damage any

tracks on the card.

When splitting the feeders, we strongly recommend

feeding both supplies from the same phase and at the

same supply voltage.

Feeds must be adequately dimensioned and fused for the loads used.

Connect incoming enclosure power to the terminals labeled MAINS. This supply MUST be

maintained 24/7.

(E) Earth/Ground (L) Live

(N) Neutral

Connect incoming projector/light fixture power to the terminals labeled SPLIT:

(E) Earth/Ground (L) Live

(N) Neutral

Advertising