Environmental specifications, Mechanical specifications – AMETEK XT Series User Manual

Page 20

Advertising
background image

Features and Specifications
Environmental Specifications

18

Operating Manual for XT Series Power Supply

Environmental Specifications

Mechanical Specifications

Maximum Remote Sense Line

Drop Compensation. (Line drop

must be deducted from the supply’s

maximum output voltage.)

0.5 V/line

Operating Ambient Temperature

0 to 30 °C with default local sensing. Above

30 °C, derate output linearly to 0 at 70 °C.

Storage Temperature Range

–55° to 85 °C

Humidity Range

Up to 80% RH non-condensing

Operating Altitude

Up to 6,500 feet (2000 m)

Storage Altitude

Up to 50,000 feet (15 000 m)

Front Panel Voltage and Current

Control

10-turn voltage and 1-turn current

potentiometers (10-turn current control

optional)

Front Panel Voltage Control

Resolution

0.02% of maximum voltage

Front Panel AC Input Power Switch Push ON/push OFF switch
Front Panel Voltage and Current

Meters

Independent 3-digit green numeric LED

display and analog bar graph displays for

current and voltage. For meter accuracy, see

Table 1.2

.

AC Input Connector Type

IEC 320 Connector, appropriate power cord for

destination country.

Front Panel Output Connector

Three binding posts: positive (+),

negative (–), and ground.

Rear Panel Output and Sense

Connector

Four terminal block.

Chassis Ground

Front panel binding post and power cord safety

ground.

Cooling

Convection cooled. Air enters the unit from the

bottom and lower sides and exits from the

upper sides and top.

Mounting

Optional rack for mounting several units in a

standard rack. Can be combined with 300 watt

series units. See

“Rack Mounting” on page 24

.

Advertising