Section 4. Operation

Introduction

Once you have installed the power supply and have connected both the AC input
power and the load as covered in Section 2 Installation, the power supply is ready to
operate.

Operating Modes, below, offers a brief explanation of Constant Voltage and
Constant Current Mode operation.

“Connecting Multiple Supplies in Series (Voltage Mode Only)” on page 35,
covers using multiple supplies.

Operating Modes

Your power supply has two basic operating modes: Constant Voltage Mode and
Constant Current Mode. The mode in which the power supply operates at any given
time depends on the combination of:

output voltage setting V

SET

output current limit setting I

SET

resistance or impedance of the attached load R

L

Figure 4.1 represents the relationships between these variables.

Figure 4.1 Operating Modes

Output
Current

Output

Voltage

Crossover Point

Constant Current
Mode Region

O

V SET

I SET

O

Constant Voltage
Mode Region

Where:

R

L

= Load Resistance

V

SET

= Output Voltage Setting

I

SET

= Output Current Setting

R

L

=

V

SET

I

SET

R

L

<

V

SET

I

SET

R

L

>

V

SET

I

SET