Installation, Fireplace placement requirements – Avalon Firestyles 864 See-Thru GS2 Installation User Manual

Page 11

Advertising
background image

Installation

(for qualified installers only)

11

© Travis Industries

4141208

100-01404

Fireplace Placement Requirements

 Fireplace must be installed on a level surface capable of supporting the fireplace and vent.
 Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet).
 This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance

produces when determining a location.

 Fireplace must be installed in a room with a minimum ceiling height of 84” (2134mm).

Clearances

 The fireplace requires a ½” (13mm) clearance from the left side of the fireplace to the framing members. No

material (insulation, framing, etc.) may be placed into this area.

 When installed, walls in front of the fireplace must be a minimum 1" (25mm) to the side of the fireplace (3-1/4”

83mm from the glass frame).

 Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.
 Fireplace must be placed so the vents below and above the glass do not become blocked.

Raised Fireplaces

 The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace (310 Lbs.

140.7 Kg) and vent.

 The base of the fireplace must be a minimum 70” (1778mm) below the room ceiling.

0" (0mm) clearance on

right side of fireplace.

NOTE: right side

standoff is optional.

1/2" (13mm)

Clearnce on left

side of

fireplace.

Platform

Optional Raised Hearth

(see "Hearth Requirements" for details)

Min. 42" (1067mm)

Fireplace Enclosure

Height