Installation

(for qualified installers only)

7

© Travis Industries

4141208

100-01404

Packing List

Propane Conversion Kit

 Log

Set

Firestop (sku 93006094)

Right Side Standoffs (2)

Wall Switch, Cover Plate, and Wire

4 AA Batteries, 1 9-Volt Battery

Insulation for Side Vent Conversion

Additional Items Required

 Direct

Vent

Gas Line Equipment (shutoff valve, pipe, etc.)

Electrical Equipment (min. 14 gauge, grounded line)

Two Grill Kits and/or Faces

Recommended Installation Procedure

Prepare the framing, making sure to leave the area around the fireplace open (see page 12). Make sure to allow for vent
installation and facing depth.

Place the fireplace into position.

Install the vent, gas line and electrical hook-up.

Finalize the framing around the fireplace.

Secure the fireplace to the framing.

Install the wall switch (see page 21) or thermostat (if applicable).

Install the drywall.

Install the hearth (if applicable).

Install the facing (if applicable).

Install the mantel (if applicable).

Finalize the installation (see page 42) and install the grill or face.

Side Standoff Installation

The two right-side standoffs included with this
fireplace are attached to the fireplace prior to
placing the fireplace into position. These standoffs
are not required for safety purposes. Their purpose
is to center the fireplace in the framed opening.
Attach the right side standoffs to the fireplace as
shown below. Remove the five screws on the side
of the fireplace, position the standoff, and secure.

NOTE: The side standoffs have obround holes that

allow for the standoff to be adjusted for
drywall of ½” (13mm) or 5/8” (18mm)
thickness. See “Nailing Brackets” on page
16.

Framing Notes

The framing dimensions included in this installation manual have been revised to include the extra 1-1/2” (39mm)
needed for the right standoffs to install correctly (44” (1118mm) width). If the fireplace opening has been framed to
the dimensions listed in the previous version of the installation manual (42-1/2” (1080mm) width), the right side
standoffs may be excluded. In this type of installation, the center of the glass will not be located in the center of the
framed opening. The center of the glass will be ¾” (19mm) from the center of the framing.