24 installation, Approved vent configurations – Avalon Firestyles 864 See-Thru GS2 Installation User Manual

Page 24

Advertising
background image

24 Installation

(for qualified installers only)

© Travis Industries

4141208

100-01404

Approved Vent Configurations

Restrictor Position

 Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and exhaust

gases. Depending upon the vent configuration, you may be required to adjust the restrictor positions. The
charts for acceptable vent configurations detail the correct vent restrictor positions.

Exhaust Restrictor Adjustment

If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust

restrictor is removed.

Loosen these two screws
on the exhaust restrictor.

Slide the restrictor to the correct

restrictor position (see the illustration
below). The screw location indicates

restrictor position. In this example, the

restrictor is set in position # 3. Tighten

the screws to secure the restrictor.

(closed) #6

# 5

# 4

# 3

# 2

(open - stock position) # 1

Left (vent) Side of Firebox

Left Wall of Firebox

Firebox Roof