Installation, Top vent configuration with vertical termination, For qualified installers only) – Avalon Firestyles 864 See-Thru GS2 Installation User Manual

Page 31

Advertising
background image

Installation

(for qualified installers only)

31

© Travis Industries

4141208

100-01404

Top Vent Configuration with Vertical Termination

 The termination must

fall within the shaded
area shown in the chart.
Use the indicated
restrictor and diffuser
positions.

 Up to four elbows (45°

or 90°) may be used.

 Only one horizontal

elbow may be used.

 May use 8" (203mm) or

6-5/8" (168mm)
diameter vent (see
page for 22 details).

5 feet (1.5m)

0 feet

0 feet

5 feet (1.5m)

0 feet

20 feet (6m)

20 feet (6m)

5 feet (1.5m)

10 feet (3m)

5 feet (1.5m)

10 feet (3m)

0 feet

15 feet (4.5m)

20' max 6m)

10 feet (3m)

15 feet (4.5m)

15 feet (4.5m)

20' max (6m)

10 feet (3m)

15 feet (4.5m)

40' max (12m)

Exhaust Restrictor # 4

Intake Restrictor # 2

Diffuser Position # 2 (stock)

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

40' max (12m)

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

Exhaust Restrictor # 3

Intake Restrictor # 2

Diffuser Position # 2 (stock)

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 90° or 45° elbow.

This is considered a

vertical elbow

Horizontal length is calculated by adding

both lengths of horizontal run

(Horizontal Length = H1 + H2).

H1

H2

Advertising
This manual is related to the following products: